Tomzn TOM7-250 250A 3 Pole MCCB Molded Case Circuit Breaker
The Tomzn TOM7-250 250A 3P MCCB is a heavy-duty AC molded case circuit breaker designed to provide overload and short-circuit protection in compatible three-phase electrical distribution systems. With a rated current of 250A and a rated operating voltage of AC 400V, this circuit breaker is suitable for applications that require dependable protection and controlled power distribution.
Part of the TOMZN TOM7 AC MCCB series, this three-pole model is designed for commercial, industrial and other electrical distribution installations. Its 50kA ultimate short-circuit breaking capacity (Icu) and 35kA service breaking capacity (Ics) make it suitable for electrical systems designed around these protection ratings.
The molded case construction provides an enclosed breaker assembly for installation in appropriate electrical panels and distribution boards. It helps protect connected circuits by interrupting excessive current caused by overloads and short circuits.
250A Rated Current Capacity
The TOM7-250 is designed for a rated current of 250A. This rating makes it suitable for compatible power distribution circuits where the expected load current and installation design require a breaker of this capacity.
A 250A rating should not be interpreted as a recommendation to operate every circuit continuously at 250A under all conditions. Actual current-carrying capacity depends on the cable size, ambient temperature, installation method, connected load and applicable electrical regulations.
The breaker must be selected according to the requirements of the electrical system. A qualified electrician or electrical engineer should verify the load calculation and protective-device coordination before installation.
Three-Pole Design for Three-Phase Systems
This product features a three-pole configuration designed for compatible three-phase AC electrical installations.
A 3P MCCB provides switching and protection across three phase conductors. It is commonly used in distribution systems where three-phase power needs to be controlled and protected.
Typical applications include:
- Three-phase commercial distribution boards
- Industrial electrical panels
- Machinery and equipment supply circuits
- Building power distribution systems
- Workshop electrical installations
- Suitable three-phase feeder circuits
The three-pole version should not be confused with a four-pole breaker. A 4P breaker includes an additional pole for the neutral conductor, while the 3P configuration is intended for the appropriate three-phase arrangement.
Overload Protection
Overload occurs when a circuit carries more current than its intended operating capacity for a sustained period. This can cause excessive heating in cables, electrical connections and connected equipment.
The TOMZN TOM7-250 MCCB provides overload protection by interrupting the circuit when the current exceeds the breaker’s applicable operating characteristics.
This helps protect electrical distribution equipment and wiring against damage caused by excessive load current.
Correct breaker selection is essential. The breaker rating and operating characteristics must be coordinated with the cable capacity and the connected electrical load.
Short-Circuit Protection
A short circuit can produce an extremely high current within a very short period. Without suitable protection, this fault current can cause serious equipment damage and create electrical safety hazards.
The TOM7-250 is designed to interrupt short-circuit currents within its specified breaking capacity.
Its published ratings include:
- Ultimate breaking capacity (Icu): 50kA
- Service breaking capacity (Ics): 35kA
These values describe the breaker’s short-circuit interruption capabilities under the specified test conditions. The prospective short-circuit current at the installation point must be assessed to ensure the selected breaker is suitable for the electrical system.
50kA Ultimate Breaking Capacity
The TOM7-250/3300 three-pole model is listed with a 50kA ultimate short-circuit breaking capacity at its specified AC operating voltage.
Icu represents the maximum short-circuit current that the breaker is designed to interrupt under the applicable test conditions. Selecting a breaker with an adequate breaking capacity is important for installations where high fault currents may occur.
The system’s available fault current, operating voltage and installation conditions should always be considered when selecting the correct MCCB.
35kA Service Breaking Capacity
In addition to its 50kA ultimate breaking capacity, the documented TOM7-250/3300 model has a 35kA service breaking capacity (Ics).
Ics indicates the short-circuit current level associated with the breaker’s service performance under specified testing conditions.
Both Icu and Ics are important when evaluating a circuit breaker for a distribution system. They should be considered together rather than treating the highest breaking-capacity figure as the only selection criterion.
AC 400V Operating Voltage
The TOM7-250 3P model is listed for AC 400V three-phase applications.
It is intended for compatible AC power distribution systems. It should not be used as a DC circuit breaker unless the exact product documentation specifically provides an applicable DC rating.
Voltage compatibility is essential because AC and DC circuit interruption requirements differ. Always check the voltage marking on the breaker and follow the manufacturer’s installation instructions.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | TOMZN |
| Product Series | TOM7 |
| Model | TOM7-250/3300 |
| Product Type | Molded Case Circuit Breaker |
| Rated Current | 250A |
| Number of Poles | 3P |
| Rated Operating Voltage | AC 400V |
| Ultimate Breaking Capacity (Icu) | 50kA |
| Service Breaking Capacity (Ics) | 35kA |
| Impulse Withstand Voltage (Uimp) | 12kV |
| Reference Ambient Temperature | 40°C |
| Product Category | AC MCCB |
| Main Protection Functions | Overload and short-circuit protection |
| Dimensions (W × H) | Approximately 105 × 165mm |
Specifications refer to the documented TOM7-250/3300 3P version. Confirm the nameplate and manufacturer’s documentation for the exact supplied unit.
Molded Case Construction
The TOM7-250 uses a molded case design that encloses the circuit breaker’s internal components. This construction is commonly used in medium- and high-current electrical distribution applications.
Molded case circuit breakers are designed to provide a compact and enclosed switching and protection arrangement. They are installed in suitable electrical panels and distribution boards according to the manufacturer’s mounting and connection instructions.
The enclosure also helps provide mechanical protection for the internal breaker assembly during normal installation and operation.
Suitable Applications
Industrial Electrical Distribution
The TOM7-250 can be used in suitable industrial distribution systems where a 250A three-pole MCCB with the required breaking capacity is specified.
Commercial Buildings
Commercial buildings may use MCCBs to protect three-phase distribution feeders and electrical equipment. The breaker must be selected according to the building’s load requirements and available fault current.
Machinery and Equipment
Suitable three-phase machinery and equipment supply circuits may require MCCB protection against overload and short-circuit faults. The breaker rating must be coordinated with the equipment specifications and motor starting requirements.
Workshops and Factories
Workshops and factories often contain multiple three-phase loads and distribution circuits. A correctly selected MCCB can provide protection and isolation for a suitable feeder or distribution section.
Main and Sub-Distribution Panels
The TOM7-250 may be considered for compatible main or sub-distribution applications where its 250A rating and breaking capacity meet the electrical design requirements.
Why Choose the Tomzn TOM7-250 250A 3P MCCB?
The TOMZN TOM7-250 combines a 250A rated current, three-pole configuration and substantial short-circuit breaking capacity in a molded case circuit breaker.
Its key specifications include AC 400V operating voltage, 50kA Icu and 35kA Ics. These characteristics make it a suitable option for electrical engineers, panel builders, industrial installers and maintenance professionals working with compatible three-phase distribution systems.
The breaker provides overload and short-circuit protection and is designed for installation in an appropriate electrical panel.
Choosing the correct MCCB is essential for protecting cables, equipment and distribution circuits. The rated current, operating voltage, breaking capacity and pole configuration must all match the requirements of the installation.
Installation and Electrical Safety
The TOM7-250 should be installed by a qualified electrician or trained electrical professional.
Before installation, verify the electrical system requirements and follow the manufacturer’s instructions.
Important precautions include:
- Isolate the electrical supply before installation or maintenance.
- Confirm that the model is TOM7-250/3300 or the correct equivalent 3P version.
- Verify the rated current and AC operating voltage.
- Check the prospective short-circuit current at the installation point.
- Ensure the breaking capacity is suitable for the system.
- Use correctly sized cables and suitable terminals.
- Tighten electrical connections according to manufacturer recommendations.
- Provide appropriate upstream and downstream protection where required.
- Inspect the breaker and connections periodically.
- Do not exceed the specified operating ratings.
The MCCB should not be selected based only on the connected load’s normal current. Cable protection, fault-current levels, coordination and applicable electrical standards must also be considered.
Frequently Asked Questions
1. What is the rated current of the TOMZN TOM7-250?
The documented TOM7-250/3300 three-pole version has a rated current of 250A.
2. Is this MCCB suitable for three-phase systems?
Yes. The 3P version is designed for compatible three-phase AC electrical distribution systems.
3. What is its rated operating voltage?
The documented three-pole TOM7-250 AC model is rated for AC 400V.
4. What is the breaking capacity?
The listed 250A 3P version has an ultimate breaking capacity (Icu) of 50kA and a service breaking capacity (Ics) of 35kA.
5. Does it provide overload protection?
Yes. The TOM7 AC MCCB series is designed to provide overload and short-circuit protection.
6. Can this breaker be used for DC applications?
Do not use this AC model for DC applications unless the exact manufacturer’s documentation confirms a suitable DC rating. AC and DC circuit breakers have different interruption requirements.
7. What is the difference between 3P and 4P MCCB?
A 3P MCCB switches and protects three phase conductors. A 4P version has an additional pole for the neutral conductor and is used where the electrical system requires four-pole switching.
8. Is it suitable for a 250A industrial feeder?
It may be suitable when the system voltage, load characteristics, cable capacity and prospective fault current match the breaker specifications. A qualified professional should confirm the selection.
Order Tomzn TOM7-250 250A 3 Pole MCCB
Choose the Tomzn TOM7-250 250A 3P Molded Case Circuit Breaker for compatible three-phase AC power distribution applications requiring overload and short-circuit protection.
With its 250A rated current, AC 400V operating voltage, 50kA ultimate breaking capacity and 35kA service breaking capacity, it is designed for suitable commercial and industrial electrical installations.
Verify the exact model marking, electrical ratings and installation requirements before ordering to ensure compatibility with your distribution system.