Tomzn TO319G 63A 3P MTS Manual Changeover Switch
The Tomzn TO319G 63A 3P Manual Changeover Switch is designed to transfer a compatible three-phase electrical load manually between two independent power sources. It provides a practical switching solution for installations that use utility electricity alongside a backup source, such as a generator or compatible solar inverter.
This TOMZN manual transfer switch features a three-position I-0-II operating mechanism. Position I connects the load to the first power source, position II connects it to the second source, and the middle position disconnects both sources. Its mechanical interlocking arrangement prevents both source paths from being connected simultaneously during normal operation.
With a rated current of 63A, a three-pole configuration and DIN rail mounting, the TO319G is suitable for selected residential, commercial and industrial three-phase power distribution applications.
Manual Transfer Between Two Power Sources
The primary function of the TOMZN TO319G is to provide manual changeover between two compatible electrical supplies.
For example, a three-phase installation may use the utility grid as its normal power source and a generator or inverter as its backup source. The operator can select the required supply using the front operating handle.
This arrangement provides direct control over which source supplies the connected load. It is particularly useful in installations where an automatic transfer system is not required and manual source selection is preferred.
Typical source arrangements include:
- Main utility supply and backup generator
- Solar inverter output and utility supply
- Two compatible independent AC supplies
- Normal and standby three-phase power sources
Both incoming supplies must meet the switch’s electrical ratings and manufacturer requirements.
Three-Position I-0-II Operating Mechanism
The TO319G uses a three-position manual operating handle.
Position I – First Power Source
When the handle is moved to position I, the switch connects the load to the first incoming power source. This position is commonly used for the normal or preferred supply.
Position 0 – OFF Position
The centre position disconnects both source paths from the load. It provides an intermediate OFF position for manual isolation during the normal switching sequence.
Position II – Second Power Source
When the handle is moved to position II, the switch connects the load to the second incoming power source. This is commonly used for a backup generator or alternative supply.
The mechanical interlocking design prevents both source connections from being selected simultaneously during normal operation. This helps avoid unintended parallel connection between the two supplies.
63A Rated Current Capacity
The Tomzn TO319G is available in a 63A configuration. This rating makes it suitable for compatible three-phase circuits designed around a maximum rated current of 63A.
The correct current rating must be selected according to the connected load, cable capacity, installation conditions and applicable electrical regulations.
A 63A rating does not mean that every installation should continuously operate at 63A. The electrician must assess the expected load and verify that the cables, terminals, upstream protection and connected equipment are suitable.
Three-Pole Design for Three-Phase Systems
The TO319G is a 3-pole manual transfer switch designed for compatible three-phase AC applications.
Each pole switches one phase conductor. This allows the device to transfer the three phase connections between the selected incoming sources.
Common applications include:
- Three-phase distribution boards
- Commercial electrical installations
- Industrial power distribution panels
- Generator backup arrangements
- Solar inverter changeover systems
- Three-phase machinery supply circuits
The 3P configuration should not be confused with a 4P model. A four-pole switch includes an additional pole for the neutral conductor. Where neutral switching is required by the electrical system design, select an appropriate 4P model instead.
Mechanical Interlocking for Source Separation
The TO319G includes a mechanical interlocking arrangement between its two switching paths.
This arrangement is designed to prevent the first and second power sources from being connected to the load at the same time through the switch’s normal operating mechanism.
This is an important feature in dual-source electrical installations because connecting two independent supplies together without a properly engineered synchronising and protection arrangement can create serious electrical hazards.
The switch should still be installed according to its wiring diagram. Correct source identification, phase sequence and electrical protection remain essential.
DIN Rail Mounting
The TO319G is designed for installation on a standard 35mm DIN rail. DIN rail mounting makes it suitable for compatible distribution boards and electrical control panels.
Its compact modular arrangement can help simplify panel installation where suitable space and clearances are available.
Before installation, the panel builder or electrician should check the device dimensions, terminal access, cable bending space and enclosure requirements.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | TOMZN |
| Model | TO319G |
| Product Type | Manual Transfer Switch (MTS) |
| Number of Poles | 3P |
| Rated Current | 63A |
| Rated Voltage | AC 400V (three-phase system) |
| Frequency | 50/60Hz |
| Insulation Voltage (Ui) | 690V |
| Impulse Withstand Voltage (Uimp) | 4kV |
| Switching Positions | I-0-II |
| Switching Operation | Manual |
| Source Interlocking | Mechanical |
| Mounting | 35mm DIN rail |
| Protection Degree | IP20 |
| Ambient Temperature | -5°C to +40°C |
| Electrical Life | Approximately 1,500 operations |
| Mechanical Life | Approximately 8,500 operations |
| Standard Listed | IEC/EN 60947-3 |
Specifications are based on published TO319G series information. Confirm the current rating, voltage marking and exact version on the supplied product before installation.
Suitable Applications
Utility and Generator Changeover
The TO319G can be used in a compatible three-phase installation where the operator needs to select between the main utility supply and a backup generator.
When the normal supply is unavailable, the operator can move the handle to the backup source position after following the appropriate operating procedure. When the preferred supply becomes available again, the load can be transferred back manually.
Solar Inverter and Grid Switching
In a suitable solar installation, the switch may be used to select between a compatible three-phase inverter output and the utility supply.
The inverter output must meet the switch’s voltage, frequency and current requirements. Follow the inverter manufacturer’s instructions and the approved electrical design when arranging the source connections.
Commercial Buildings
Shops, offices and commercial premises may use manual transfer switches where an alternative power supply is available and manual source selection is appropriate.
The three-pole configuration is intended for compatible three-phase circuits.
Industrial Electrical Panels
Industrial installations may require manual selection between normal and standby supplies for selected distribution circuits or equipment.
The TO319G can be considered where its current rating, voltage rating and switching category meet the application requirements.
Workshops and Machinery
Compatible three-phase machinery supply circuits may use a manual changeover arrangement to select between two power sources. The machinery’s starting current and operating requirements should be considered before selecting the switch.
Understanding the 1-0-2 Switching Sequence
The 1-0-2 switching arrangement provides three clearly defined operating positions.
In position 1, the first supply is connected to the load. In position 0, both supply paths are disconnected. In position 2, the second supply is connected to the load.
This arrangement allows the operator to disconnect the load from one source before selecting the alternative source.
For dual-source wiring, follow the manufacturer’s specified incoming and outgoing terminal arrangement. Incorrect connections can affect the intended transfer operation and create electrical hazards.
Important Difference Between an MTS and an MCB
The TO319G is a manual transfer and isolation switch. Although some product listings describe it as a breaker-type changeover switch, it should not be treated as a substitute for a properly rated miniature circuit breaker or molded case circuit breaker.
Its main purpose is to select between two power sources and provide the specified switching and isolation functions.
It does not automatically provide the overload and short-circuit protection expected from a dedicated protective circuit breaker.
Suitable upstream and downstream protective devices must be selected separately according to the electrical installation design.
Installation and Electrical Safety
Installation should be performed by a qualified electrician or trained electrical professional.
Before connecting the TO319G, verify that both incoming supplies are compatible with the device and that the load is suitable for its 63A rating.
Important precautions include:
- Isolate both power sources before installation or maintenance.
- Confirm the exact TO319G 3P 63A model.
- Follow the manufacturer’s wiring diagram.
- Identify the normal and standby supply terminals correctly.
- Check phase sequence and supply compatibility.
- Use suitable cable sizes and secure terminal connections.
- Provide appropriate upstream overcurrent protection.
- Confirm whether the neutral conductor requires separate switching.
- Install the device in a suitable electrical enclosure.
- Do not exceed the rated current or voltage.
- Test the changeover operation under safe conditions.
The IP20 protection rating is intended for installation inside a suitable enclosure. The switch should not be exposed directly to water, dust or unsuitable environmental conditions.
Why Choose the Tomzn TO319G 63A 3P Manual Changeover Switch?
The TOMZN TO319G provides a straightforward manual solution for transferring a compatible three-phase load between two power sources.
Its 63A rated current, three-pole configuration, mechanical interlocking and three-position operating mechanism make it suitable for selected dual-source electrical installations.
The DIN rail mounting arrangement also makes it convenient for integration into compatible distribution boards and control panels.
For users who prefer direct manual control instead of an automatic transfer system, the TO319G offers a practical way to select between normal and backup power supplies.
Correct electrical selection, wiring and separate circuit protection are essential for safe and reliable operation.
Frequently Asked Questions
1. What is the rated current of the TOMZN TO319G?
This product is the 63A version of the TO319G manual transfer switch.
2. Is the TO319G suitable for three-phase systems?
Yes. The 3P version is designed for compatible three-phase AC power systems.
3. Is this an automatic transfer switch?
No. The TO319G is a manual transfer switch. The operator changes the source using its operating handle.
4. Can it switch between WAPDA and a generator?
It can be used in a compatible three-phase utility-and-generator arrangement when the electrical ratings and wiring configuration are suitable.
5. What do I-0-II positions mean?
Position I selects the first power source, position 0 disconnects both source paths, and position II selects the second power source.
6. Does the switch connect both sources simultaneously?
The mechanical interlocking arrangement prevents both source paths from being selected simultaneously through normal operation.
7. Does it provide overload and short-circuit protection?
Do not rely on the TO319G as a replacement for dedicated overcurrent protection. Suitable circuit breakers or fuses must be installed separately.
8. Can it be installed on a DIN rail?
Yes. The TO319G is designed for standard 35mm DIN rail mounting.
9. Is the 3P version suitable when neutral switching is required?
The 3P version switches three phase conductors. If the installation requires neutral switching, an appropriately rated 4P transfer switch should be considered.
Order Tomzn TO319G 63A 3P MTS Manual Changeover Switch
Choose the Tomzn TO319G 63A 3P Manual Changeover Switch for compatible three-phase installations that require manual transfer between two power sources.
With its 63A rating, I-0-II operating positions, mechanical interlocking and 35mm DIN rail mounting, it provides a practical changeover solution for suitable grid, generator and inverter applications.
Confirm the exact model, voltage rating, neutral arrangement and wiring requirements before ordering.



Reviews
There are no reviews yet.