Tomzn TOM7Z 2P 125A DC MCCB Circuit Breaker
Product Overview
The Tomzn TOM7Z 2P 125A DC MCCB is a two-pole molded case circuit breaker designed to provide overcurrent protection in compatible direct current (DC) electrical systems. It is part of the TOMZN TOM7Z series and is intended for high-current applications such as solar photovoltaic installations, battery storage systems, and DC power distribution networks.
DC electrical systems require dedicated protective devices because interrupting direct current presents different challenges compared with AC circuits. A DC-rated MCCB is designed to interrupt fault current within its specified voltage and breaking-capacity limits.
The TOM7Z-125 series offers a 125A current option and a two-pole configuration. Its molded case construction provides a practical solution for electrical panels where reliable DC circuit protection is required.
This product is commonly advertised with a 1000V DC rating. However, different TOMZN documentation and product variants also show other voltage configurations. Always verify the exact voltage marking and wiring diagram on the supplied breaker before installation.
Key Features
- Brand: TOMZN
- Model: TOM7Z-125/2300
- Product Type: DC Molded Case Circuit Breaker (MCCB)
- Rated Current: 125A
- Pole Configuration: 2 Pole (2P)
- Advertised Voltage: Up to 1000V DC, subject to variant verification
- Ultimate Breaking Capacity (Icu): 35kA for the documented 125A version
- Service Breaking Capacity (Ics): 22kA for the documented 125A version
- Protection: Overload and short-circuit protection
- Application: Solar PV, battery storage, and compatible DC distribution systems
125A High-Current DC Protection
The 125A rating makes this MCCB suitable for DC circuits designed to operate within its specified current and voltage limits.
High-current DC systems require carefully selected protective equipment. An incorrectly rated breaker may fail to provide the required protection or may be unable to interrupt a fault safely.
The Tomzn TOM7Z-125 is designed for installations that require a higher-current DC protective device. Its rated current should be matched with the expected operating current, cable capacity, connected equipment, and system fault level.
The correct MCCB selection also depends on ambient temperature, installation conditions, and the manufacturer’s specified operating characteristics.
Two-Pole DC Circuit Breaker Design
The Tomzn TOM7Z features a two-pole configuration designed for compatible DC circuit arrangements.
A 2P DC MCCB provides two switching poles that operate together through the breaker’s mechanism. Depending on the system design and manufacturer’s wiring instructions, these poles can be used to disconnect the designated DC conductors.
Correct pole connection is particularly important in high-voltage DC applications. The voltage rating may depend on the approved connection arrangement, and the breaker must be wired according to its printed polarity and terminal diagram.
Never assume that the two poles can be connected in any arrangement or that the advertised maximum voltage applies to every wiring configuration.
Overload Protection
An overload occurs when a circuit carries more current than it is designed to handle for an extended period.
Excessive current can cause cables, terminals, and connected electrical equipment to overheat. If the condition continues, it may damage electrical components and create a fire risk.
The thermal protection mechanism in a suitable MCCB responds to sustained overcurrent and disconnects the circuit when the operating conditions reach its specified trip characteristics.
The Tomzn TOM7Z-125 DC MCCB is designed to provide overload protection for compatible DC circuits. Correct selection of the current rating and conductor size is essential for effective protection.
Short-Circuit Protection
A short circuit can cause a sudden and extremely high current flow. This can damage equipment and create dangerous electrical conditions.
The magnetic protection mechanism in a thermal-magnetic MCCB is designed to respond rapidly to high fault current and interrupt the circuit.
Breaking capacity is one of the most important specifications when selecting a DC MCCB. It indicates the maximum fault current the device is designed to interrupt under specified test conditions.
For the documented TOM7Z-125 version, the listed breaking capacities are:
- Icu: 35kA ultimate short-circuit breaking capacity
- Ics: 22kA service short-circuit breaking capacity
These values must be confirmed against the exact product label and matching manufacturer datasheet before the breaker is selected for a particular installation.
Suitable Applications
The Tomzn TOM7Z 2P 125A DC MCCB may be considered for compatible applications such as:
- Solar photovoltaic (PV) systems
- Solar DC distribution panels
- Battery storage and battery bank systems
- DC power distribution equipment
- Compatible inverter and battery circuits
- Renewable energy installations
- Industrial DC electrical systems
- Other high-current DC applications
The breaker must be selected according to the actual system voltage, expected current, fault level, and required protection characteristics.
It should only be used in DC applications within the manufacturer’s approved ratings. Do not substitute it for an AC breaker or use it in an AC circuit unless TOMZN explicitly approves that application.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | TOMZN |
| Model | TOM7Z-125/2300 |
| Product Type | DC MCCB |
| Rated Current | 125A |
| Pole Configuration | 2P |
| Advertised Voltage | Up to 1000V DC; verify variant |
| Insulation Voltage (Ui) | 1000V in documented series specifications |
| Impulse Withstand Voltage (Uimp) | 12kV in documented series specifications |
| Ultimate Breaking Capacity (Icu) | 35kA |
| Service Breaking Capacity (Ics) | 22kA |
| Protection Functions | Overload and short circuit |
| Typical Applications | Solar PV, batteries, DC distribution |
Important specification note: TOMZN documentation for the TOM7Z-125 series includes different voltage arrangements depending on the version and pole configuration. Some technical tables show 600V DC for the 2P configuration, while other 2P TOM7Z-125/2300 documentation and product listings specify 1000V DC. Confirm the exact Ue voltage printed on the supplied breaker and its corresponding wiring diagram. Do not rely on the model name alone.
Molded Case Construction
The molded case construction provides a protective housing around the internal switching and contact mechanisms.
This design is commonly used in distribution equipment where a durable circuit breaker is required for higher-current applications.
The TOM7Z series is intended for installation in compatible electrical panels and enclosures. Its construction supports organized DC distribution and protection arrangements when correctly installed.
The enclosure and surrounding electrical panel should provide suitable protection against accidental contact, dust, moisture, and environmental conditions relevant to the installation.
Benefits of Using a DC MCCB
A dedicated DC MCCB is an important component in a properly designed solar or battery electrical system.
The Tomzn TOM7Z series offers several practical benefits:
Dedicated DC Protection
The breaker is designed for compatible DC applications, where a specifically rated interruption mechanism is required.
High-Current Capability
The 125A version is suitable for circuits designed around its specified current rating.
Two-Pole Switching
The 2P configuration allows the designated conductors to be switched together according to the manufacturer’s approved connection arrangement.
Fault Protection
Its thermal-magnetic protection mechanism is designed to respond to overload and short-circuit conditions.
Multiple Applications
It can be considered for compatible solar, battery, renewable energy, and DC distribution installations.
Installation Guidelines
The Tomzn TOM7Z DC MCCB should be installed by a qualified electrician familiar with high-voltage DC systems.
Before installation, check the following:
- Confirm the model is TOM7Z-125/2300.
- Verify the rated current is 125A.
- Confirm the exact DC working voltage.
- Check the Icu and Ics breaking-capacity ratings.
- Follow the manufacturer’s polarity and terminal connection diagram.
- Confirm the approved two-pole wiring arrangement.
- Select cables and terminals suitable for the operating current.
- Tighten connections according to the manufacturer’s specified torque.
- Install the breaker securely in a compatible electrical enclosure.
Always isolate the power source before installation, inspection, or maintenance. Solar panels can continue producing electricity in daylight, while battery systems may deliver very high fault currents.
Important Safety Information
High-voltage DC installations can present serious electrical hazards. The correct protective device must be selected according to the system’s maximum operating voltage, current, and available short-circuit current.
Never exceed the breaker’s specified voltage, current, or interruption capacity.
Follow the manufacturer’s wiring diagram carefully. Incorrect polarity or pole connections can compromise the breaker’s ability to interrupt DC fault current safely.
A DC MCCB should not be treated as a substitute for every other protective device in the installation. Additional fuses, isolators, or other protection may be required according to the system design and applicable electrical regulations.
Professional installation and proper coordination with upstream and downstream protection devices are essential for safe operation.
Buy Tomzn TOM7Z 2P 125A DC MCCB Breaker
Choose the Tomzn TOM7Z 2P 125A DC MCCB for compatible high-current DC protection requirements in solar PV, battery storage, and electrical distribution systems.
Its two-pole configuration, molded case construction, and overload and short-circuit protection functions make it a practical option for appropriately designed DC installations.
Before ordering, confirm the exact voltage rating and breaking capacity printed on the supplied unit. Selecting the correct variant ensures that the breaker matches your electrical system requirements.



Reviews