Tomzn 400A 2P DC MCCB Molded Case Circuit Breaker 1500V TOM7Z-400
The Tomzn 400A 2P DC MCCB is a high-current DC molded case circuit breaker designed to provide electrical protection in compatible direct-current power systems. It is part of the TOMZN TOM7Z high-voltage DC MCCB range and is suitable for applications where a properly rated DC circuit breaker is required to help protect electrical circuits against overload and short-circuit conditions.
The TOM7Z-400/2300 variant is listed with a rated current of 400A and a rated operating voltage of DC 1500V. With a two-pole configuration and a high short-circuit breaking capacity, it can be considered for appropriately engineered solar photovoltaic installations and other compatible DC power distribution systems.
When selecting a high-current breaker, it is important to check more than its ampere rating. System voltage, fault current, circuit configuration, cable capacity, installation method and manufacturer specifications all play an important role in choosing suitable protection equipment.
Key Features of Tomzn 400A 2P DC MCCB
- 400A rated current: Designed for compatible high-current DC applications.
- 2-pole configuration: Two-pole construction for suitable DC circuit arrangements.
- DC 1500V rated operating voltage: Intended for compatible high-voltage DC systems.
- 65kA ultimate breaking capacity (Icu): Listed ultimate short-circuit breaking capacity.
- 50kA service breaking capacity (Ics): Listed service short-circuit breaking capacity.
- 12kV impulse withstand voltage (Uimp): Listed impulse withstand rating.
- Non-polarized design: Manufacturer information describes flexible top or bottom input connection.
- Overcurrent protection: Helps protect a compatible circuit against excessive current.
- Short-circuit protection: Designed to interrupt specified short-circuit fault conditions.
These ratings relate to the specified TOM7Z 1500V model family. Always check the actual product label and technical documentation supplied with the breaker before using these figures for system design.
400A DC Circuit Protection
A circuit breaker is an important part of an electrical protection arrangement. It is designed to interrupt current when specified fault conditions occur, helping reduce the risk of damage to wiring and connected equipment.
The Tomzn 400A 2P DC MCCB is intended for DC applications that require a high-current protective device. Its 400A rating identifies the rated current of the specified variant; it does not mean that the breaker is suitable for every installation carrying up to 400A. The correct selection depends on the system design, operating conditions, conductor ratings and required protection coordination.
For high-current installations, the breaker should be selected by a qualified electrical professional who can confirm that its voltage rating, interruption capacity and protection characteristics are suitable for the available fault current and the connected equipment.
2-Pole Design for DC Applications
This circuit breaker features a 2-pole configuration. Pole arrangement is an important consideration in DC protection because the circuit design and grounding arrangement determine how conductors must be switched and protected.
The two-pole design should be matched to the electrical diagram and the requirements of the particular DC system. Installers should follow the manufacturer’s connection instructions and ensure that the selected breaker is suitable for the circuit’s voltage and current arrangement.
The TOMZN product information describes the TOM7Z 1500V series as non-polarized, meaning the input connection may be made from the top or bottom while maintaining normal operation. Nevertheless, installation must follow the instructions for the exact model supplied. Do not assume that wiring arrangements for another DC breaker series are interchangeable.
DC 1500V Rated Operating Voltage
Voltage compatibility is essential when selecting a DC circuit breaker. The TOM7Z-400/2300 variant is listed with a rated operating voltage of DC 1500V.
This makes the specified version relevant to suitably designed high-voltage DC applications, including compatible solar photovoltaic systems. The system’s maximum possible DC voltage must remain within the breaker’s approved operating limits under the applicable conditions.
A breaker rated for DC service should not automatically be used in an AC circuit, and an AC breaker should not be substituted for a DC breaker without explicit manufacturer approval. DC interruption requirements differ from AC requirements, so selecting equipment with the correct DC rating is particularly important.
Suitable Applications
Depending on the system design and the manufacturer’s approved application conditions, the Tomzn 400A 2P DC MCCB may be considered for:
- Solar photovoltaic DC power systems
- High-current DC distribution arrangements
- Compatible renewable energy installations
- DC power supply equipment
- Suitable wind or hydropower DC applications
- Other engineered DC circuits requiring a compatible 2-pole protective device
For solar installations, the breaker must be selected according to the electrical design of the PV array, inverter, battery arrangement and DC distribution equipment. The rated voltage, current, short-circuit capacity and required isolation arrangements should all be checked before installation.
Short-Circuit Breaking Capacity
The listed TOM7Z-400/2300 specifications include an ultimate short-circuit breaking capacity (Icu) of 65kA and a service short-circuit breaking capacity (Ics) of 50kA.
These ratings describe the breaker’s specified short-circuit interruption performance under the relevant test conditions. They are important when evaluating whether a protective device is appropriate for a particular electrical installation.
The available fault current at the installation point must be assessed by a qualified professional. A high breaking-capacity figure alone does not establish that a breaker is suitable for every DC system. The voltage, circuit configuration, installation conditions and other manufacturer limits must also be considered.
Non-Polarized Connection Design
TOMZN describes the TOM7Z 1500V DC MCCB as having a non-polarized design. According to the product information, the device can operate normally with input supplied from either the top or the bottom.
This can offer flexibility when planning compatible electrical panel layouts. However, installers should always consult the connection diagram and installation instructions for the exact breaker model. Correct conductor termination, tightening torque, clearance and protective enclosure arrangements remain essential.
Product Specifications
The following details are listed for the TOM7Z-400/2300 400A 2-pole 1500V DC variant:
- Brand: TOMZN
- Product type: DC Molded Case Circuit Breaker (MCCB)
- Series: TOM7Z 1500V
- Model reference: TOM7Z-400/2300
- Rated current: 400A
- Number of poles: 2P
- Rated operating voltage: DC 1500V
- Insulation voltage (Ui): 1500V
- Impulse withstand voltage (Uimp): 12kV
- Ultimate short-circuit breaking capacity (Icu): 65kA
- Service short-circuit breaking capacity (Ics): 50kA
- Operating temperature listed in available documentation: -5°C to +40°C
- Protection functions: Overcurrent and short-circuit protection
- Connection design: Non-polarized, subject to model instructions
Specifications should be checked against the manufacturer’s current documentation and the actual product nameplate. Accessories, dimensions, terminal details, warranty and included components should be confirmed with the seller before ordering.
Why Choose a TOMZN DC MCCB?
Choosing a suitable DC molded case circuit breaker is an important step in building a reliable electrical protection system. A correctly selected MCCB provides a defined means of interrupting specified fault conditions and can form part of a broader protection arrangement.
The Tomzn 400A 2P DC MCCB combines a high-current rating, two-pole configuration and listed DC 1500V operating voltage in the TOM7Z-400/2300 variant. Its listed short-circuit breaking ratings make it a product worth considering for compatible high-current DC applications.
Buyers should compare the required system ratings with the product’s nameplate and technical documents rather than choosing a breaker on current rating alone. Correct protection coordination and professional installation are especially important in high-voltage DC systems.
Installation and Safety Guidelines
High-voltage DC installations can present serious electrical hazards. Installation, inspection and maintenance should only be performed by qualified personnel using appropriate safety procedures.
Before installation:
- Confirm the exact model number and rated current printed on the breaker.
- Verify that the system’s maximum DC voltage is within the approved rating.
- Check that the available fault current is compatible with the breaker’s breaking capacity.
- Confirm the correct pole arrangement and wiring configuration.
- Select conductors and terminals suitable for the installation current and conditions.
- Follow the manufacturer’s wiring diagram, terminal requirements and tightening instructions.
- Ensure that the enclosure, mounting arrangement and required clearances are appropriate.
- Isolate all power sources and follow safe working procedures before installation or maintenance.
Never work on an energized high-voltage DC circuit. Do not exceed the product’s rated limits or use it in an application that has not been approved by the manufacturer.
Order Tomzn 400A 2P DC MCCB from Asbaab.pk
If you are looking for a high-current DC molded case circuit breaker for a compatible solar or DC power installation, explore the Tomzn 400A 2P DC MCCB at Asbaab.pk.
Before placing your order, confirm the TOM7Z-400/2300 model reference, 400A rated current, DC 1500V rating and required installation configuration. You should also verify stock availability, warranty, included accessories and delivery details with the seller.
Choose electrical protection equipment according to your system’s technical requirements and consult a qualified professional whenever you are unsure about compatibility.



Reviews